Ultrasonic Flow Meters

FIXED INSTALLATION WETTED SENSOR TRANSIT TIME

(Transit time is for clean water)

PENSTOCK FLOW METERS FOR HYDRO PLANTS

rittmeyer-thin-logo
rittmeyer-risonic-2000Risonic Modular Multi-Path Water Flow Meters for large pipes such as penstocks, tunnels and channels. Suitable for pipe diameters up to 11 meters (36-feet) and open channels 7 to 70 meters wide, these meters achieve accuracies to +/- 0.5% of rate. The Risonic Modular flow meters meet the standards of the IEC-41 and ASME PTC-18 codes for hydro-electric turbine efficiency testing.

In 2015 Cascadia supplied a Rittmeyer Risonic Modular eight path, turbine efficiency testing transit time flow meter to Jimmie Creek Hydro Project in the Upper Toba Valley, BC. Cascadia has supplied Risonic flow meters to more than 15 hydro projects since 2000.

long-lake-8-path-opt-768x576

Additional Information: Rittmeyer_Risonic Modular Flow Meterpdf


FIXED CLAMP-ON TRANSIT TIME

Risonic modular clamp-on transit timeRisonic Modular Clamp-ON – Non-intrusive flow measurement (no drilling, no interruption of operation) Magnetic frame eliminates mounting straps and also works on partly exposed pipes. Durable and long-term solution, option for adhesive mounting of magnetic frame. Measuring accuracy of up to 1.5% of measured flow. Flow measurement in both directions (pumped-storage power plant). Advanced mathematical calculations (total flow, average of delta flow, etc.) Web server for easy configuration and remote diagnosis. IEC 60870-5-104 and Modbus RTU/TCP communication. Mobile metering with possibility for battery-powered operation.

Additional Information: Transit-Time Ultrasonic Flowmeter RISONIC clamp-on Flyer E22_040_0082534_001_02_optpdf


PORTABLE-HAND HELD- CLAMP-ON TRANSIT TIME

ncm603The HHT-05 Hand Held clamp-on Ultrasonic Transit Time flowmeter is Ideal for monitoring full pipe clean liquid applications. Suitable for metal and plastic pipes. Magnetic transducers install easily on ferrous metal pipes and it includes a strap on mounting kit for non-ferrous and plastic pipes. Typical applications are; river water, well water, chilled water, hot water, potable water, cooling tower water, de-ionized water, sea water and acids.

Additional Information: NCM-603 Portable Handheld Flowmeterpdf


FIXED CLAMP-ON DOPPLER (F-100-DFM5)

6b6ddd60The F-100-DFM5 installs easily on metal and plastic pipes that are full of liquid. This flow meter is recommended for dirty liquids including wastewater, sewage, sludge, paper stock, slurries and more. Application requirements are for liquids with suspended solids or aeration greater than 100 microns (75ppm).

Additional Information: Greyline DFM 5.0 Doppler Flow Meterpdf


PORTABLE CLAMP-ON ULTRASONIC DOPPLER

portable-clampon-dopplerUltrasonic Doppler flow meters are for; dirty or aerated liquids, some slurries and lubrication fluids, in full pipes.
Use it to monitor and balance flow, or to troubleshoot flow problems in full pipes. It is ideal to evaluate performance of in-line flow meters and can be installed, calibrated and started-up in minutes. Use it for projects where a permanent flow meter is not required or to temporarily replace installed flow transmitters.

Additional Information: Greyline Portable Doppler HH PDFMpdf


FIXED AREA VELOCITY DOPPLER

q-eye-psc-mt-150x150HydroVision GmbH Q-Eye PSC MT designed for full or partially full pipes 100 – 2000 mm ( 4 to 80 in.) or open channels with flow depths 40 to 2000 mm (1.5 to 80 in.)